We the team of 'Pneumatic engineers, from "Drytech" offers RD Series refrigerated drying unit can deliver the compressed air with quality of air as per ISO specification recommended to various applications.

Exessive leakages in compressed air piping ! Sluggish pneumatic tools / machines operation !! Malfunctioning of precious pneumatic instruments !!! Etc.

Are unlimited problems faced by compressed air users in industries. The root cause of these problems is moisture, oil and dust particles in compressed air.

We the team of 'Pneumatic engineers, from "Drytech" offers RD Series refrigerated drying unit (RDU). the RDU can deliver the compressed air with quality of air as per ISO specification recommended to various applications.



Salient Features

  • Compact and Suitable for indian atmospheric conditions.
  • Complete dryer operation overview through front panel display.
  • Inlet / outlet digital Compressed air temp indication as an option.
  • Least pressure drop.
  • Adopted enviorment friendly refrigerant system.
  • Reliable, automatic drain valve with by pass arrangement.
  • Compact design with maintenance friendly work man ship.

Operation

We Compressed air enters into Compact, highly, efficient corrugated fin & tube 3 in 1 type heat exchanger, where Compressed air is cooled by refrigerant cycle upto +30c. At this temperature moisture from gasious form to into liguid form and separates by in-built moisture separator. This condensate will be effectively removed by automatic drain valve, further air is filtered by fine filter combination and dry air is delivered to down application.

Model Aifflow* Max. Operating Pressure Power Supply Version** Air Conn. Dimensions (mm)
  m3 / min cfm kg /cm2 psi v/ph/Hz     L W H
S10R 0.28 10 16 228 230 / 1 / 50 AIR COOLED   ½" 480 400 625
S20R 0.57 20 16 228 230 / 1 / 50 AIR COOLED ½" 480 400 625
S35R 1.13 40 16 228 230 / 1 / 50 AIR COOLED 3/4" 480 400 625
S50R 1.42 50 16 228 230 / 1 / 50 AIR COOLED 3/4" 480 400 625
S60R 1.70 60 16 228 230 / 1 / 50 AIR COOLED 3/4" 480 400 625
S80R 2.27 80 16 228 230 / 1 / 50 AIR COOLED 1" 680 560 850
S100R 2.83 100 16 228 230 / 1 / 50 AIR COOLED 1" 680 560 850
S125R 3.54 125 16 228 230 / 1 / 50 AIR COOLED 1 ½" 680 560 850
S150R 4.25 150 16 228 230 / 1 / 50 AIR COOLED 1 ½" 680 560 850
S200R 5.66 200 16 228 230 / 1 / 50 AIR COOLED 1 ½" 750 650 1000
S250R 7.08 250 16 228 230 / 1 / 50 AIR COOLED   1 ½" 750 650 1000
S300R 4.49 300 16 228 230 / 1 / 50 AIR COOLED 2" 950 850 1250
S350R 9.91 350 16 228 230 / 1 / 50 AIR COOLED 2" 950 850 1250
S450R 12.74 450 16 228 230 / 1 / 50 AIR COOLED 2" 950 850 1250
S550R 15.57 550 16 228 230 / 1 / 50 AIR COOLED 2 ½" 1000 900 1400
S650R 18.41 650 16 228 230 / 1 / 50 AIR COOLED 2 ½" 1000 900 1400
S750R 21.24 750 16 228 230 / 1 / 50 AIR COOLED 2 ½" 1000 900 1400
S900R 25.48 900 16 228 230 / 1 / 50 AIR COOLED 3" 1250 1000 1550
S1000R 28.32 1000 16 228 230 / 1 / 50 AIR COOLED 3" 1250 1000 1550
S1100R 31.15 1100 16 228 230 / 1 / 50 AIR COOLED 3" 1250 1000 1550

Note

Data for the dryers above 1100 cfm are available on request *FAD based on 45oC inlet temperature and 40oC ambient temperature at 7 kg/cm2 operating pressure and 30c to 7oc pressure and 30c to 7oc pressure dew point ** Water cooled models starting from 550 cfm and above are available on request Due to continuous engineering improvements, technical specifications are subject to change without prior notice.

Compressed Air Water Cooled After Coolers

Performance Data Based On Design Data

  • Ambient Temprature : 40oc
  • Intel Temprature : 45oc
  • Intel Pressure : 7 kg / cm2
  • Pressure Dew Point : 3-7oc
  • Max. Ambient Temprature : 50oc
  • Min. Ambient Temprature : 5oc
  • Max. Intel Temprature : 65oc
  • Max. Intel Pressire : 16 kg / cm2xxc

Flow Correction Factor

During the selection of the dryer, capacity correction to be used when operating conditions differ from performance data To get dryer capacity based on conditions multiply capacity by Correction factors (X,Y,Z)


Ambient Temprature
Temp. 20 30 3 40 45
CF 1.12 1.08 1.04 1 0.96
Inlet Temperature (Y)
Temp. 35 40 45 50 55
CF 1.06 1.03 1 0.9 0.75
Inlet Pressure (Z)
Pressure 6 7 9 10.5 12.5
CF 0.95 1 1.08 1.13 1.18


Selection Factors

Conversion factors at various intel pr.

Op. pr (kg/cm2g) Pr. Factors intel tempR (0 C) Ambient tempR (0 C)
4 0.63 35 1.00 35 1.00
5 0.75 40 0.82 40 0.92
6 0.87 45 0.69 45 0.84
7 1.00 50 0.58    
8 1.13      
9 1.25    
10 1.35